ebmpapst D2E146-HT67-01 230VAC 400W 1.75A 577CFM 2100RPM Air Purifier Centrifugal Blowers Flange Mount

$152.00

SKU: 1600065512224 Brand:

Description

The ebm-papst D2E146-HT67-01 is a high-performance dual-inlet centrifugal blower engineered for demanding thermal management and air purification systems. Utilizing a 2-pole, single-phase AC motor with a motor capacitor, this forward-curved centrifugal fan delivers optimized aerodynamic efficiency and high static pressure capabilities. Designed with Original Engineering standards, it ensures seamless Technical Compatibility with existing HVAC, industrial cooling, and high-capacity air filtration architectures.

Technical Specifications:
Manufacturer: ebm-papst
Model Number: D2E146-HT67-01
Fan Type: Centrifugal Blower, Dual Inlet, Forward Curved
Impeller Diameter: Ø 146 mm
Nominal Voltage: 230 VAC
Phase: 1~
Frequency: 50 Hz / 60 Hz
Power Consumption: 400 W
Nominal Current: 1.75 A
Maximum Airflow: 577 CFM (980 m³/h)
Rated Speed: 2100 RPM
Mounting Type: Flange Mount
Protection Class: IP44
Insulation Class: F
Motor Bearing: Maintenance-free Ball Bearing
Ambient Temperature Range: -25 °C to +55 °C
Weight: 4.5 kg
Housing Material: Galvanized Sheet Steel
Impeller Material: Galvanized Sheet Steel
Motor Protection: Thermal overload protector (TOP) internally connected

Industrial Application:
The D2E146-HT67-01 is specifically deployed in high-resistance airflow systems requiring consistent volumetric delivery against elevated static pressure. Primary applications include commercial air purifiers, cleanroom ventilation units, electronics cabinet cooling, and industrial heat exchangers. The dual-inlet geometry maximizes air intake efficiency within confined installation envelopes, while the galvanized steel construction prevents corrosion in high-humidity environments.

Procurement and Lifecycle:
This component guarantees exact Technical Compatibility for direct replacement of failing blowers in critical infrastructure. With optimized Lead Time protocols, facility managers can minimize downtime. Rely on Original Engineering to maintain system integrity, acoustic performance, and long-term operational reliability.

Key Attributes
Mounting: Free Standing
Voltage: 230V
Blade Material: Sheet steel, hot-dip galvanised
Customized support: OEM, ODM
Warranty: 1 Year
After-sales Service Provided: Online support
Model number: D2E146-HT67-01
Place of origin: Germany
Brand name: Ebmpapst
Type: Centrifugal Fan
Nominal voltage: 230(V)
Bearing Type: Ball Bearing
Power consumption: 355/400 (w)
Speed: 1850/2100 (r/min)
Current: 1.55/1.75 (A)
Fan Size: 146 mm
Type of protection: IP 20
Insulation class: "F"
Housing Material: Plastic

Packaging and Delivery
Selling Units: Single item
Single package size: 35X35X26 cm
Single gross weight: 70.000 kg

ebmpapst D2E146-HT67-01 230VAC 400W 1.75A 577CFM 2100RPM Air Purifier Centrifugal Blowers Flange Mount

ebmpapst D2E146-HT67-01 230VAC 400W 1.75A 577CFM 2100RPM Air Purifier Centrifugal Blowers Flange Mount

ebmpapst D2E146-HT67-01 230VAC 400W 1.75A 577CFM 2100RPM Air Purifier Centrifugal Blowers Flange Mount

ebmpapst D2E146-HT67-01 230VAC 400W 1.75A 577CFM 2100RPM Air Purifier Centrifugal Blowers Flange Mount

ebmpapst D2E146-HT67-01 230VAC 400W 1.75A 577CFM 2100RPM Air Purifier Centrifugal Blowers Flange Mount

ebmpapst D2E146-HT67-01 230VAC 400W 1.75A 577CFM 2100RPM Air Purifier Centrifugal Blowers Flange Mount

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Fans Maintenance and upkeep

1. The use environment should always be kept clean and tidy, the surface of the fan should be kept clean, there should be no sundries in the inlet and outlet air outlets, and the dust and other sundries in the fan and pipes should be cleaned regularly;

2. The fan can only operate under the condition that it is completely normal, and at the same time, it is necessary to ensure that the capacity of the power supply facilities is sufficient and the voltage is stable.

3. During the operation of the fan, if it is found that the fan has abnormal sound, the motor is seriously heated, the shell is live, the switch trips, and cannot be started, it should be stopped immediately for inspection. In order to ensure safety, maintenance is not allowed during the operation of the fan, and a test run should be carried out for about five minutes after the overhaul to confirm that there is no abnormal phenomenon before starting the operation;

4. The fan should be stored in a dry environment to avoid moisture on the motor. When the fan is stored in the open air, there should be defensive measures. In the process of storage and handling, the fan should be prevented from bumping to avoid damage to the fan.

FAQ

Kralvo is a trusted supplier of industrial and home appliance spare parts, offering high-quality components for cooling systems, HVAC units, vacuum cleaners, printers, compressors, CNC machines, and more. We provide reliable products, competitive prices, and fast worldwide delivery.